VIRGIN MEDIA - BIRMINGHAM, UK

Daikin 3 pipe heat recovery air conditions were installed to supplement the existing base build 4 pipe fan coils. The indoor units comprised of ducted and wall mounted units and were connected to external condensing units located within a purpose built external fenced compound.

Daikin VAM heat Recovery ventilation units were installed to supplement the existing base build ventilation system to bring the fresh air supply in the building to current building regulations of 10L\S per person. Both the Daikin VAM units and Daikin VRV systems were all controlled from a central Daikin icontroller located within the plant room to allow the building manager to remotely operate the systems.

Virgin Media

DALEHEAD FOODS - SPALDING, LINCOLNSHIRE, UK

Dalefarm Foods

The supply, installation and commissioning of No. 1 Mitsubishi VRF Heat pump system, to provide heating/cooling to the new canteen area. This is via 5No. Void ducted type indoor units, located within a purpose built bulkhead.

With supply air ducted into the sloping ceiling and discharged via linier diffusers, the return air is via linier diffusers mounted in the front of the bulk head with the bulk head being used a plenum box for mixing the return air and the fresh air (via the AHU) to all the indoor units. Remote room sensors have been located at the return air diffuser to enable a more accurate control.

Supply and commissioning of 3No. Mitsubishi CAHV heat pump boilers, to provide the under floor heating, hot water demand, and hot water to a heating coil on the ventilation Air Handling Unit.

With a hot water demand at 700C and under floor heating provided at 450C. The 3No Mitsubishi Heat Pump Boilers are piped together as one flow /return enabling the entire system to modulate from one, up to three systems as the demand calls for.

GURU NANAK TEMPLE - SMETHWICK, WEST MIDLANDS, UK

Hitachi 3 pipe VRF heat recovery air conditions were installed, within the second floor classrooms. For the main hall and wedding hall areas IVX multi Split systems were selected with void ducted mounted units. The systems are connected to external condensing units located on the roof top plant areas. The Hitachi systems were controlled from central controllers with an interface connected to the BMS system.

Additional to AC systems, Hitachi manufactured air cooled condensers had been selected to serve the DX coil on the fresh air AHU, to temper the fresh air provided to the main hall and wedding hall areas, these were supplied complete with interface kits.

Guru Nanak Temple Smethwick

HENDON PENTHOUSE APARTMENTS - HENDON, LONDON, UK

Hendon Penthouse Apartments

To accommodate the length of pipe run from the top floor penthouse apartments to the lower level car park where the external condensing unit plant was to be located, a Daikin VRV system was selected, which was able to accommodate the long pipe run.

The indoor units were all the ducted type that were located and concealed in purpose built bulkheads within the plasterboard ceiling, so as to not detract from the high quality apartment finishers.

The indoor units were all fitted with an infra-red sensor that allowed the occupant to remotely operate the air conditioning system.

VELOCITY - WEYBRIDGE, SURREY, UK

Daikin 3 pipe VRV heat recovery air conditions were installed to serve the New Multi Storey Office Buildings.

Then, an overall total of 252 indoor void ducted mounted units were installed connected to external 3pipe VRV heat recovery condensing units located within the roof top plant areas.

The Daikin VRV systems are controlled from Daikin I controller, centralized controllers, located at each floor level, with overall control and monitoring of the systems via a BacNet gateway.

Velocity Weybridge

DANIEL DEPARTMENT STORE - WINDSOR, BERKSHIRE, UK

Daikin 3 pipe VRV heat recovery air conditions were installed to serve the new department store.

For the retail areas void ducted mounted units were installed, with wall mounted units selected for the second floor office areas. The systems are connected to external 3pipe heat recovery condensing units located on the roof top plant areas. The Daikin VRV systems were controlled from a central Daikin I controller located on each floor level with overall control and monitoring via a BacNet gateway.

Additional to VRV systems a Daikin air cooled condenser has been selected to serve the Dx coil on the fresh air AHU, selected to temper the fresh air provided to the retail areas, supplied complete with and interface kit.

Daniel Department Store

TESCO - LEICESTER, UK

Tesco Leicester

Daikin Split type heat pump air conditions were installed to serve the back of house office area. The indoor units comprised of Cassette and Wall mounted units connected to external condensing units located within the roof top plant areas.

The Daikin systems were controlled individually via infra red type controllers.